Project Description

Multi Free Match Outdoor

DC INVERTER A++ R32
New generation of R32 DC Inverter ERP Free match systems.

Maximum flexibility coming from a wide choice of indoor units and convenient installation.  A perfect solution for large apartments or small office buildings.

• Capacity range from 14.000 Btu up to 42.000 Btu for ODU Units.

• Connect up to 5 indoor unit of any type to the outdoor unit.

• Small dimension and wide variety of indoor unit types and capacity.

• DC Inverter compressors provide a high energy efficiency.

• Reliable cooling and heating at low ambient temperature of up to -15 Celcius

• Wide operation range starting from -15 Celcius in cooling and heating.

Specifications

FACTORY MODEL AM2-H14/4DR3 AM2-H18/4DR3 AM3-H21/4DR3 AM3-H27/4DR3 AM4-H36/4DR3 AM5-H42/4DR3
Operation COOLING HEATING COOLING HEATING COOLING HEATING COOLING HEATING COOLING HEATING COOLING HEATING
Nominal Capacity kW 4,10 4,80 5,30 5,60 6,20 6,60 7,90 8,20 10,50 11,00 12,00 13,00
Nominal Capacity Btu/h 13.989 16.378 18.084 19.107 21.154 22.519 26.955 27.978 35.826 37.532 40.944 44.356
Pdesign  (C/A/W)* kW 4,10 3,50 5,30 4,80 6,20 5,70 7,90 6,90 10,50 9,30 12,00 9,30
Capacity Range kW 1,80 – 4,51 2,05 – 5,28 2,00 – 5,83 2,21 – 6,16 2,20 – 6,71 2,39 – 7,26 2,30 – 8,69 2,45 – 9,02 2,50 – 11,00 2,67 – 11,20 2,77 – 12,70 2,96 – 13,10
Capacity Range Btu/h 6.142 – 15.388 6.995 – 18.015 6.824 – 19.892 7.541 – 21.017 7.506 – 22.895 8.155 – 24.771 7.848 – 29.650 8.359 – 30.776 8.530 – 37.532 9.110 – 38.214 9.451 – 43.332 10.100 – 44.800
Power Input  (min-nom-max) kW 1,24 (2,10)  1,15 (2,10) 1,75 (2,30)  1,54 (2,30)  1,92 (2,80)  1,78 (2,80)  2,46 (3,40)  2,20 (3,40)  3,95 (5,30)  3,15 (5,30)  4,45 (5,64)  3,75 (5,64)
Current Input (nom) A 5,60 (9,55) 5,22 (9,55) 7,95 (10,45) 7,00 (10,45) 8,72 (12,72) 8,10 (12,72) 11,20 (15,45) 12,36 (15,45) 17,95 (24,09) 14,31 (24,09) 20,22 (25,64) 17,04 (25,64)
Annual Consumption kWh/ann 233 1.209 263 1.653 331 1.822 440 2.394 598 3.163 685 3.144
SEER – SCOP(C/A/W) – Energy Class W/W 6,1 A++ – /4,0 A+/ – 7,0 A++ – /4,0 A+/ – 6,5 A++ – /4,3 A+/ – 6,3 A++ – /4,0 A+/ – 6,1 A++ – /4,1 A+/ – 6,1 A++ – /4,1 A+/ –
Ambient Temperature Range oC -15 ~52℃ -15 ~24℃ -15 ~52℃ -15 ~24℃ -15 ~52℃ -15 ~24℃ -15 ~52℃ -15 ~24℃ -15 ~52℃ -15 ~24℃ -15 ~52℃ -15 ~24℃
Power supply V-Ph-Hz 230V ~ 1N – 50 Hz 230V ~ 1N – 50 Hz 230V ~ 1N – 50 Hz 230V ~ 1N – 50 Hz 230V ~ 1N – 50 Hz 230V ~ 1N – 50 Hz
Power Connection Cable ODU.-IDU. / Com. mm2 ODU 3×2,5 / 2x 4×1,5 ODU 3×2,5 / 2x 4×1,5 ODU 3×2,5 / 3x 4×1,5 ODU 3×2,5 / 3x 4×1,5 ODU 3×4 / 4x 4×1,5 ODU 3×4 / 5x 4×1,5
Compressor Type GMCC Rotary GMCC Rotary GMCC Rotary GMCC Rotary GMCC Rotary GMCC Rotary
Throttling Method Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Sound Pressure Level ODU. dB(A) 54 55 56 58 61 61
Sound Power ODU dB(A) 61 62 65 65 68 68
Refrigerant charge kg R32 – 1,07 R32 – 1,10 R32 – 1,25 R32 – 1,20 R32 – 2,30 R32 – 2,30
Diameter Liquid-Gas Connection Pipe inch 2×1/4″ – 2×3/8″ 2×1/4″ – 2×3/8″ 3×1/4″ – 3×3/8″ 3×1/4″ – 3×3/8″ 4×1/4” – 4×3/8” 5×1/4” – 5×3/8”
Total max Piping Distance / per IDU m 40 / 25 40 / 25 60 / 30 60 / 30 80 / 35 80 / 35
Max Height Difference ODU-IDU / IDU-IDU m 15 / 10 15 / 10 15 / 10 15 / 10 15 / 10 15 / 10
Min / Max number of connected IDU pcs 2 / 2 2 / 2 2 / 3 2 / 3 2 / 4 2 / 5
Additional refrigerant charge g/m 20 (in plus 10m) 20 (in plus 10m) 20 (in plus 10m) 20 (in plus 10m) 20 (in plus 10m) 20 (in plus 10m)
Outdoor Unit Dimension LxHxD /Weight mm/kg 800 x 545 x 315 / 34 800 x 545 x 315 / 36 834 x 655 x 328 / 44 834 x 655 x 328 / 46 985 x 808 x 395 / 74 985 x 808 x 395 / 75

*  Colder, Average, Warmer climate zones for heating operation