FZ SERIES
DC Inverter A++, R32
Freedom Series is AUX competitive entry level series, equipped with numerous advantages.
It is a standard energy efficiency series coming with a silver strip minimal and low-noise indoor unit with LED information display, and a reliable and compact Outdoor unit.
Special Features
iFeel
Freedom Series comes with special technology in temperature monitoring. Instead of monitoring the preferred temperature at the installation position, high upon on the wall, your air conditioner can monitor room temperature on the remote control. So, by keeping it next to you, you can enjoy your chosen conditions wherever you are sitting.
i-Clean
This function works when the unit is Off. When selecting this operation, the unit turns into cooling for 15mins, to create frost, then operates in heating to turn frost into water, and finally turns to the Antifungus operation to dry completely. The result is a clean indoor unit.
AIC WiFi
Freedom Series is a WiFi ready product. The unit is ready to accept the optional plug-and-play WiFi Module working on IOT 2.0 generation APP, available for IOS and ANDROID, allowing you to access your air conditioner from anywhere you chose.
PERFECT AIR
Freedom Series is equipped with many options intended to bring the highest quality of air. “High-Density” dust filters improve both filtrating but also circulation efficiency. The “PM 2,5 Filters” purify air by retaining 99,9% of bacteria. The “Golden Fin” treatment of indoor Heat Exchanger (optional) prevents build-up of moisture, bacteria and unpleasant odors. Last but not least, the AUTO Clean patented technology performs Heat Exchanger auto cleaning. Now you can enjoy perfect air quality for all AUX Brand products.
ENERGY EFFICIENCY
Freedom Series offers a competent A++ energy efficiency Class. The AUX DC Inverter compressor system including GMCC compressors and DC fan motors controlled by Renesas micro-chips, running on latest AUX Sine wave logic, bring out a great result year-round
0.5W STANDBY
As a result of the drive for energy efficiency improvement Freedom series units consume a mere 0,5W per hour on standby mode.
FUNGUSPROOF
This function allows the indoor unit fan to operate for a few minutes after shut down, to dry the unit from moisture caused by the cooling operation. This way you can make sure that less moisture and bacteria is buildup in the indoor unit, to remain cleaner for next time.
Specifications
F-SERIES Panel
MODEL CODE | SET | ASW-H09B4/FZR3DI-EU | ASW-H12B4/FZR3DI-EU | ASW-H18B4/FZR3DI-EU | ASW-H24B4/FZR3DI-EU | ||||
MODEL CODE | IDU | ASW-H09B4/FZR3DI-EU | ASW-H12B4/FZR3DI-EU | ASW-H18B4/FZR3DI-EU | ASW-H24B4/FZR3DI-EU | ||||
MODEL CODE | ODU | AS-H09B4/FZR3DI-EU | AS-H12B4/FZR3DI-EU | AS-H18B4/FZR3DI-EU | AS-H24B4/FZR3DI-EU | ||||
Operation | COOLING | HEATING | COOLING | HEATING | COOLING | HEATING | COOLING | HEATING | |
Nominal Capacity | kW | 2,60 | 2,80 | 3,50 | 3,50 | 5,25 | 5,50 | 7,00 | 7,00 |
Nominal Capacity | Btu/h | 8.871 | 9.554 | 11.942 | 11.942 | 17.913 | 18.766 | 23.884 | 23.884 |
Pdesign (C/A/W)* | kW | 2,60 | .-/2,20/- | 3,20 | .-/2,40/- | 5,30 | .-/4,40/- | 6,70 | .-/5,70/- |
Capacity Range | kW | 0,50-2,90 | 0,50-3,10 | 0,80-3,50 | 1,00-3,60 | 1,20-5,40 | 1,20-5,80 | 1,40-7,30 | 0,90-7,10 |
Capacity Range | Btu/h | 1.706-9.890 | 1.706-10.577 | 2.729-11.942 | 3.412-12.283 | 4.094-18.424 | 4.094-19.789 | 4.776-24.907 | 3.070-24.225 |
Power Input (min-nom-max) | W | 100-950-1.300 | 100-1.240-1.400 | 100-1.130-1.600 | 300-1.240-1.600 | 900-1.730-2.000 | 200-1.890-2.200 | 130-2.300-3.000 | 200-2.500-2.700 |
Current Input (nom) | A | 3,56 | 3,32 | 4,82 | 4,28 | 7,35 | 6,60 | 9,75 | 8,67 |
Annual Consumption | kWh/ann | 149 | .-/752/- | 184 | .-/826/- | 283 | .-/1.535/- | 341 | .-/1.940/- |
SEER – SCOP(C/A/W) – Energy Class | W/W | 6,15 A++ | .-/4,10A+/- | 6,10 A++ | .-/4,07A+/ | 6,57 A++ | .-/4,02A+/- | 6,89 A++ | .-/4,11A+/- |
Ambient Temperature Range | oC | 16~48 | -15~32 | 16~48 | -15~32 | 16~48 | -15~32 | 16~48 | -15~32 |
Power supply | V-Ph-Hz | 230V ~ 1N – 50 Hz | 230V ~ 1N – 50 Hz | 230V ~ 1N – 50 Hz | 230V ~ 1N – 50 Hz | ||||
Power Connection Cable ODU.-IDU. / Com. | mm2 | 3×1,5 – NO / 4×1,5 | 3×1,5 – NO / 4×1,5 | 3×2,5 – NO / 4×1,5 | 3×2,5 – NO / 4×1,5 | ||||
Compressor Type / Brand | GMCC Rotary | GMCC Rotary | GMCC Rotary | HIGHLY Rotary | |||||
Throttling Method | Capillary | Capillary | Capillary | Capillary | |||||
Air Flow Volume | m3/h | 634/560/491/421 | 634/560/491/421 | 661/580/518/456 | 1.310/1.150/1.028/905 | ||||
Sound Pressure Level IDU (H/M/L) – ODU. | dB(A) | 42/38/34/29 – 51 | 42/38/34/29 – 52 | 47/41/38/34 – 56 | 47/43/40/36 – 58 | ||||
Sound Power IDU (H/M/L) – ODU | dB(A) | 52/47/43/38 – 61 | 52/47/43/38 – 61 | 58/51/48/44 – 66 | 57/53/50/46 – 68 | ||||
Diameter Liquid-Gas Connection Pipe | inch | 1/4″ – 3/8″ | 1/4″ – 3/8″ | 1/4″ – 1/2″ | 1/4″ – 5/8″ | ||||
Refrigerant charge (precharge/after 5m) | R32 – 0,53kg / 20g/m | R32 – 0,60kg / 20g/m | R32 – 1,28kg / 20g/m | R32 – 1,44kg / 30g/m | |||||
Max Distance /Height Connection Pipe | m | 20 / 10 | 20 / 10 | 20 / 10 | 25 / 15 | ||||
Indoor Unit Dimension LxHxD /Weight | mm/kg | 750x285x211 / 7,5 | 750x285x211 / 8 | 900x310x225 / 12 | 1.082x330x233 / 15 | ||||
Outdoor Unit Dimension LxHxD /Weight | mm/kg | 730x545x285 / 25 | 730x545x285 / 25 | 800x545x315 / 35 | 900x700x350 / 45 |
* Colder, Average, Warmer climate zones for heating operation